Measuring Stations
All-in-one measuring station ready for plug-in, consisting of
- Multifunction meter D300 with Consumption probe C400
- Multifunction meter D300 with Dew point probe H410/415/416
- Multifunction meter D300 with both Consumption & Dew Point probes
Stationary consumption measurement, available with and without measuring section.
Special Features
- All-in-one solution, easy installation
- 2 displays: Actual flow and total air consumption
- Easy installation and removal of the sensor under pressure
- Highest accuracy due to 5 point precision calibration
- Output 4 to 20 mA for m³/h, pulse output for m³
- Easy to handle: -Inner diameter freely adjustable in DS 300
- 2 alarm values freely adjustable
- Optical display in case of alarm
- Consumption counter resettable
Technical Data C300/D300
Dimensions: 92 x 92 x 70 mm, IP 65 (panel mounting)
Inputs: 2 digital inputs for C300 resp. H300
Interface: USB, data collector
Keyboard: 4 keys
Power supply: 90-260 VAC, 50-60 Hz
Accuracy: 4%
Alarm outputs:2 relays, 230 VAC, 3 A
Operating temp.: 0...50 °C
Transportation temp.: -20...70 °C
OPTIONS
Wall housing: 118 x 115 x 93 mm, IP 65
Data logger: 500,000 measured values start-stop time, meas. rate freely adjustable
RS 485: up to 256 x DS 300 connectable, evaluation at PC via Soft in graphic and table form
2 additional input 4 to 20 mA, 0 to 10 V, plug-in cards: Pt100, NiCr-Ni
Data recording and evaluation at the PC – up to 256 flow stations
Special Features
- Up to 256 flow stations connectable via RS 485
- Up to 500,000 measured data are stored in each single instrument D300
- Online readout of the data of each measuring site at the PC (current flow in m³/h, total air consumption in m³)
- Readout of the data via USB data collector, up to 64 x D300 (128 MB)
- Reprogramming of S 300 via USB data collector
- The following BUS systems can be realised:
- Profibus DP Slave USB
- Interbus Slave
- Modbus RS 485 Slave
- Modbus on TCP
- CANopen
- DeviceNet
Compressed Air Analysis with D300
With the multifunction measuring instrument D300 the user gets a survey on the whole compressed air system
All relevant measured data for an economic operation of the compressed air station at a glance:
- Actual air consumption in m³/h or m³/min
- Total air consumption in m³
- Pressure dew point in °Ctd
- Line pressure in bar
- Current consumption in A
- Temperature in °C
Sensor Options for D300
Pre-installed pipe sections with ball valve
Special features • Measuring section made of stainless steel 1.4301 incl. ball valve
- up to DN 65 (G 2 1/2") with external thread ISO 228/1
- from DN 80 with weld neck flange according to DIN 2633
In order to maintain the accuracy stipulated in the data sheets, the sensor must be inserted in the centre of a straight pipe section with unhindered flow characteristics. Unhindered flow characteristics are achieved if the sections in front of the sensor (inlet) and behind the sensor (outlet) are sufficiently long, absolutely straight and lack obstructions such as edges, seams, curves etc. Careful attention must be paid to the design of the outlet section as obstructions can cause counter-flow turbulence as well as turbulence in the direction of the flow